• EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale
  • EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale
  • EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale
  • EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale
  • EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale
  • EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale
  • EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale
  • EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale

EMP001 24V 250W 1700RPM 1.40Nm 12.25Amp B3/B14/B34/B5 Brushed brush bl DC motor for sale

  • USD $286 - $374 / Piece Get Latest Price
  • HF Motion
  • EMP001
  • Zhejiang, China
  • 50 Piece / Pieces
  • T/T Credit Card
  • 500 Piece / Pieces per Month
  • Ningbo or Shanghai
Product Details
Certification:CCC, CE, ROHS, UL, VDE Torque:1.40Nm, 1.40Nm Construction:Permanent Magnet
Continuous Current(A):12.25Amp Speed(RPM):1700RPM Commutation:Brush
Product Description

Product Display

VIEW MORE PLS CONTACT US >>>

Other Products

Process Flow

About Us

Packing&Transport

Q:Motor has been running then fails to start,what to do?A:Likely cause: Fuse or circuit breaker is tripped. 

      What to do: Replace the fuse or reset the breaker.

     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.      What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.      What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

      Likely cause: Controller may be defective.       What to do: Verify voltage is coming out of the controller.

Q: On initial installation, motor fails to start up,what to do?A: Likely cause: Motor is incorrectly wired      What to do: Verify that the motor is wired correctly.

     Likely cause: No output power from controller.      What to do: Measure voltage coming from the controller.

     Likely cause: Motor is damaged and the armature is rubbing against the magnets.      What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

Q:  Motor takes too long to accelerate,what to do?A:  Likely cause: Motor controller not properly set.      What to do: Adjust the acceleration trim pot of the controller.

     Likely cause: Brushes are worn.      What to do: Verify brush length.

     Likely cause: Bearings may be defective.      What to do: Inspect bearings. Noisy or rough bearings should be replaced.

Q:  Motor runs in the wrong direction,what to do?A:  Likely cause: Incorrect wiring      What to do: Interchange the two motor leads.

Q:  Motor runs OK but has a clicking noise,what to do?A:  Likely cause: Suspect a burr on the commutator.      What to do: Remove burr from commutator using a commutator stone.